International Journal of Electrical, Electronics and Data Communication (IJEEDC)
eISSN:2320-2084 , pISSN:2321-2950
.
Follow Us On :
current issue
Volume-12,Issue-1  ( Jan, 2024 )
ARCHIVES
  1. Volume-11,Issue-12  ( Dec, 2023 )
  2. Volume-11,Issue-11  ( Nov, 2023 )
  3. Volume-11,Issue-10  ( Oct, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 133
Paper Published : 1712
No. of Authors : 4737
  Journal Paper


Paper Title :
Optimum Capacitor Allocation in three Phase Unbalanced Radial Distribution System with Harmonics and Resonance Consideration using PSO Algorithms

Author :Ayusta Lukita Wardani, Ontoseno Penangsang, Rony Seto Wibowo

Article Citation :Ayusta Lukita Wardani ,Ontoseno Penangsang ,Rony Seto Wibowo , (2017 ) " Optimum Capacitor Allocation in three Phase Unbalanced Radial Distribution System with Harmonics and Resonance Consideration using PSO Algorithms " , International Journal of Electrical, Electronics and Data Communication (IJEEDC) , pp. 6-11, Volume-5,Issue-9

Abstract : Distribution system connects between generation system and transmission system to the load. Power quality in distribution system can affect the flow of electric distribution. Decrease in power quality can be caused of low power factor, voltage drop, line loses and harmonic. Installation of capacitors can overcome the power quality problems when placement is appropriate. In a distorted system the presence of a capacitor may aggravate the harmonic level and cause either parallel or series resonance. In this research, capacitor placement and capacities are limited by minimum voltage, maximum reactive power load, THD and resonance index. Resonance index based on limit of capacitor loading according to IEEE standard. This scheme is tested on a distorted three-phase unbalanced distribution system which is have under voltage characteristics. The simulation result shows the installation of capacitor using PSO algorithm by considering harmonics and resonance index is capable to fulfill standard of THD that is 4.6929 % and decrease of active power loss equal to 19.74% and minimum voltage 0.95 pu. Keywords - line loses, resonance index, THD, PSO.

Type : Research paper

Published : Volume-5,Issue-9


DOIONLINE NO - IJEEDC-IRAJ-DOIONLINE-9399   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 74
| Published on 2017-11-24
   
   
IRAJ Other Journals
IJEEDC updates
Volume-12,Issue-1(Jan ,2024) Want to join us ? CLick here http://ijeedc.iraj.in/join_editorial_board.php
The Conference World

JOURNAL SUPPORTED BY

ADDRESS

Technical Editor, IJEEDC
Department of Journal and Publication
Plot no. 30, Dharma Vihar,
Khandagiri, Bhubaneswar, Odisha, India, 751030
Mob/Whatsapp: +91-9040435740