Paper Title :Experimental Study on Flooding Limitation in Vapour-Vapour-Liquid Three Phase Direct Contact Condenser
Author :Hameed B. Mahood Al-Muhammedawi
Article Citation :Hameed B. Mahood Al-Muhammedawi ,
(2017 ) " Experimental Study on Flooding Limitation in Vapour-Vapour-Liquid Three Phase Direct Contact Condenser " ,
International Journal of Advances in Science, Engineering and Technology(IJASEAT) ,
pp. 22-26,
Volume-5, Issue-4, Spl. Iss-1
Abstract : Experiments to study the limitation of flooding inception in vapour-vapour-liquid three-phase direct contact
condenser have been carried out in a counter-current small diameter vertical condenser. The total column height and
diameter were 70 cm and 4 cm, respectively. Only 48 cm has been used as an active three-phase direct contact condenser
height. Vapour pentane with three different initial temperatures (40, 43.5, and 47.5 oC) and water with a constant
temperature (19 oC) have been used as a dispersed phase and a continuous phase, respectively. Five different continuous
phase mass flow rates and four different dispersed phase mass flow rates have been tested throughout the experiments.
Dimensionless correlation based on the previous common flooding correlation is proposed to calculate the up-flow flooding
inception of the three-phase direct contact condenser
Keywords - Three-Phase direct contact Heat Exchanger, Three-Phase Condenser, Flooding Phenomena
Type : Research paper
Published : Volume-5, Issue-4, Spl. Iss-1
DOIONLINE NO - IJASEAT-IRAJ-DOIONLINE-10064
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 23 |
| |
Published on 2018-01-24 |
|