International Journal of Management and Applied Science (IJMAS)
.
Follow Us On :
current issues
Volume-10,Issue-1  ( Jan, 2024 )
Past issues
  1. Volume-10,Issue-1  ( Jan, 2024 )
  2. Volume-9,Issue-12  ( Dec, 2023 )
  3. Volume-9,Issue-11  ( Nov, 2023 )
  4. Volume-9,Issue-10  ( Oct, 2023 )
  5. Volume-9,Issue-9  ( Sep, 2023 )
  6. Volume-9,Issue-8  ( Aug, 2023 )
  7. Volume-9,Issue-7  ( Jul, 2023 )
  8. Volume-9,Issue-6  ( Jun, 2023 )
  9. Volume-9,Issue-5  ( May, 2023 )
  10. Volume-9,Issue-4  ( Apr, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 119
Paper Published : 5065
No. of Authors : 10504
  Journal Paper


Paper Title :
Acceptable Illuminance Level Attributes to Learning Satisfaction in Classroom

Author :Fadli Arabi, Elina Mohdhusini, Raja Nur Syaheeza, Raja Mohdyazit, Yakubu Aminu Dodo, Mohd Zin Kandar

Article Citation :Fadli Arabi ,Elina Mohdhusini ,Raja Nur Syaheeza ,Raja Mohdyazit ,Yakubu Aminu Dodo ,Mohd Zin Kandar , (2018 ) " Acceptable Illuminance Level Attributes to Learning Satisfaction in Classroom " , International Journal of Management and Applied Science (IJMAS) , pp. 61-66, Volume-4,Issue-3

Abstract : The importance of student’s satisfaction in school is to highlight the parameter that related to physical of buildings and learning area. Natural lighting is important to human where the daylight shall cause visual discomfort and performance in classrooms. Due to address the issue, the acceptable illuminance level is needing to be identified to increase performance in occupants’ satisfaction. Illuminance level in learning spaces should not be neglected where in the form of human values, comfort and culture are to be focused as a main criterion in student’s performance. Daylighting in an educational space can be improved in order to enhance the student’s performance and promotes a better health and performance due to suitable level of visual comfort. The aim of this study is to investigate the student’s performance in classroom with minimum performance zone in minimum Window-to-Wall Ratio (WWR). The physical conditions; WWR of less than 25%, to 40% of typical of classroom and illuminance level that ranged from 300-400 lux were identified to be sufficient daylight level. Pilot studies have been conducted in typical classroom of KolejPermataInsan where the effects of acceptable illuminance level that contribute to visual performance is identified. Qualitative survey has been conducted on the student’s perception toward visual comfort and obtaining the comparison on performance from visual test. The illuminance level for the classroom was recorded using an LED data logger. Findings from the case study showed less than 20% openings in classrooms affect students minimum acceptable of illuminance level. There will significant contrast between internal luminance to external luminance if WWR is more than 70%. While the ideal WWR for classroom should be not more than 40% to achieve the optimum performance zone and acceptable illuminance level. The findings contribute towards the identification of an acceptable visual comfort ranges for students and design recommendations for optimum performance zone in a classroom in Malaysia. Keywords - Keywords-visual comfort, acceptable illuminance level, performance zone, daylighting, classroom.

Type : Research paper

Published : Volume-4,Issue-3


DOIONLINE NO - IJMAS-IRAJ-DOIONLINE-11611   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 65
| Published on 2018-05-11
   
   
IRAJ Other Journals
IJMAS updates
IJMAS -THANK YOU ALL FOR CONTRIBUTING YOUR PAPER TO IJMAS MAY ISSUE. ALL AUTHORS ARE REQUESTED TO GET THEIR HARD COPY NOW.
The Conference World
Facebook

JOURNAL SUPPORTED BY