Paper Title :Control Strategies used for a 3 Phase 4 Wire Topology for Transformerless Grid Tied Inverter
Author :Ku.Kiran V. Kondawar, P. R. Khatri
Article Citation :Ku.Kiran V. Kondawar ,P. R. Khatri ,
(2018 ) " Control Strategies used for a 3 Phase 4 Wire Topology for Transformerless Grid Tied Inverter " ,
International Journal of Electrical, Electronics and Data Communication (IJEEDC) ,
pp. 1-8,
Volume-6,Issue-10
Abstract : Three different current control strategies which are PI-controller in dq0-reference frame, PID controller and
hysteresis controller for a three-phase-four-wire solar inverter. We discussed in this paper and compared concerning their
influences on the grid harmonics, and the resulting power losses in the power devices. In this paper we discuss about the PIcontroller
in dq0-reference frame, PID controller and hysteresis controller.
Keywords - Photovoltaic, dq0, 3 Phase 4 Wire, Three-Phase-Four-Wire.
Type : Research paper
Published : Volume-6,Issue-10
DOIONLINE NO - IJEEDC-IRAJ-DOIONLINE-13940
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 76 |
| |
Published on 2018-12-27 |
|