International Journal of Mechanical and Production Engineering (IJMPE)
.
Follow Us On :
current issues
Volume-12,Issue-1  ( Jan, 2024 )
Past issues
  1. Volume-11,Issue-12  ( Dec, 2023 )
  2. Volume-11,Issue-11  ( Nov, 2023 )
  3. Volume-11,Issue-10  ( Oct, 2023 )
  4. Volume-11,Issue-9  ( Sep, 2023 )
  5. Volume-11,Issue-8  ( Aug, 2023 )
  6. Volume-11,Issue-7  ( Jul, 2023 )
  7. Volume-11,Issue-6  ( Jun, 2023 )
  8. Volume-11,Issue-5  ( May, 2023 )
  9. Volume-11,Issue-4  ( Apr, 2023 )
  10. Volume-11,Issue-3  ( Mar, 2023 )

Statistics report
Apr. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 130
Paper Published : 2388
No. of Authors : 6802
  Journal Paper


Paper Title :
Performance Evaluation of Mist Spray Direct Evaporative Cooler through Experimentation and its Comparasion with Conventional Evaporative Cooler with Honeycomb Pad Arrangement

Author :Sapali S. N. Avinash M. Deshmukh, Vyankatesh D. Chavan

Article Citation :Sapali S. N. Avinash M. Deshmukh ,Vyankatesh D. Chavan , (2019 ) " Performance Evaluation of Mist Spray Direct Evaporative Cooler through Experimentation and its Comparasion with Conventional Evaporative Cooler with Honeycomb Pad Arrangement " , International Journal of Mechanical and Production Engineering (IJMPE) , pp. 4-9, Volume-7,Issue-3

Abstract : In residential building, air conditioning system is one of the major energy consuming appliances. Evaporative cooling systems are mostly preferred as an alternative to compressor-based air conditioning systems, sacrificing comfort to a certain level. The performance of a Mist Spray Direct Evaporative Cooler (MSDEC) is evaluated basically on four parameters viz. Reduction in air temperature, saturation efficiency, cooling capacity, and noise level. This research article focuses on development of MSDEC, its performance evaluation and comparison with the Conventional Evaporative Cooler with Honeycomb Pad Arrangement (CECHPA) under the same test conditions. Results indicate performance of MSDEC is improved significantly in respect of a drop in temperature, saturation efficiency and enhanced cooling capacity with a considerable saving in energy input, reduction in water consumption and noise level. The unit is almost free from fungus and mosquitoes as it requires no water storage. Keywords - Mist Spray, Direct Evaporative Cooling, Spinning Disc.

Type : Research paper

Published : Volume-7,Issue-3


DOIONLINE NO - IJMPE-IRAJ-DOIONLINE-15197   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 75
| Published on 2019-06-06
   
   
IRAJ Other Journals
IJMPE updates
Volume-12,Issue-1 (Jan, 2024 )
The Conference World

JOURNAL SUPPORTED BY