Paper Title :Analysis Of SAR Impact On A Tissue Cube With Graphene Based IFA
Author :Jemima Priyadarshini.S, D.Jude Hemanth
Article Citation :Jemima Priyadarshini.S ,D.Jude Hemanth ,
(2016 ) " Analysis Of SAR Impact On A Tissue Cube With Graphene Based IFA " ,
International Journal of Advances in Science, Engineering and Technology(IJASEAT) ,
pp. 141-144,
Volume-4,Issue-2
Abstract : The Graphene based Nano conductive antennas are the one of the recent antennas pioneering in areas of research.
The analysis of radiating structure and exposure area draws attention towards bio medical concerns and health issues. This
paper intends to conduct the experimental analysis of Graphene based Inverted F Antenna (G-IFA) with a sample cubic
tissue model. Specific Absorption of Radiation SAR parameter is estimated for the designed setup for its operating GSM
frequency at 900 MHz The human tissue model with dielectric properties are applied over a cubic structure that is designed
and placed above the graphene based radiating structure. On the exposure analysis SAR is investigated over the varying
frequencies between 6 MHz and 12 MHz and are recorded. 1g, 10 g and overall SAR are also estimated in this procedure.
The variation of exposure over varying frequency range depicts its impact on absorption [1].
Index Terms- Dielectric Properties, SAR, MOM, G-IFA.